Ulead MEDIASTUDIO PRO 8.0 - SMART COMPOSITOR DESIGNER Especificaciones Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 165
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
Operating Manual MA VPU V 6.0
MA Lighting Technology GmbH Dachdeckerstr. 16 D-97297 Waldbüttelbrunn www.malighting.dePage 32
3.4 Connection States
When you launch MA VPU it tries to connect to a session with the same ID.
The four possible states of the connection are indicated by the heart in the status bar. The
blinking of the heart indicates the communication between the desk and MA VPU.
Heart is broken and red:
No connection to a session established
Heart is blinking green:
MA VPU has joined a session as slave
Heart is blinking blue:
MA VPU is the master of a session. The creation of a session with MA VPU can
be used to transfer all data of a .gvs or .gz file (MA VPU 1 or 2 formats) to a desk
or onPC. If the loading is completed, the desk automatic becomes the master
and MA VPU gets the slave.
Heart is blinking yellow (grandMA 1 only):

mode.
In opposite to the slave mode no session data will be exchanged with the desk.
ATTENTION: With the start of a new session (Create) the session founder overwrites all data
of the other members. I.e. if a new session is founded by the MA VPU all data in the desk
will be overwritten!
If more than one console, visualizer or onPC editor is connected to the network the
connections to the equipment will have to be properly assigned.
The communication between consoles, visualizer, VPU applications and onPC editors
takes place in sessions.
A session has only one founder. This is e.g. the master. On connection the founder
transfers its data (fixture types) to the slaves.
From then on, all session members are synchronized and have equal rights. If a
fixture is edited in the slave the change is reflected in the master and vice-versa.
Devices not assigned to any session are not in the list.

Series 1 specification:
A Session always has one master and up to 31 Slaves, i.e. max. 32 devices. For example a
slave can be another MA desk, an NSP, a grandMA onPC application, the grandMA 3D

because similar to the Artnet protocol a VPU station is only receiving data.
Series 2 specification:
A Session always has one master and up to 199 stations.
Vista de pagina 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 164 165

Comentarios a estos manuales

Sin comentarios